ASTM D5084 PDF

GeoTesting Express is a provider of Soil Testing Services – ASTM D, Standard Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous. All the Controls products ASTM D standard. Enter now!. Standard Test Method for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter.

Author: Mejinn Gardagul
Country: Guatemala
Language: English (Spanish)
Genre: Art
Published (Last): 9 August 2009
Pages: 243
PDF File Size: 20.59 Mb
ePub File Size: 20.20 Mb
ISBN: 114-9-14664-418-8
Downloads: 94740
Price: Free* [*Free Regsitration Required]
Uploader: Dalkis

Flow volumes shall be measured by a graduated accumulator, graduated pipette, vertical standpipe in conjunction with an electronic pressure transducer, or other volume-measuring device of suitable accuracy.

These hydraulic systems are as follows:. d584

The new subsection states that such CV hydraulic systems should not be used to study the time or pore-? Therefore, where-ever practical use stainless steel? If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. The paper shall have a negligibly small hydraulic impedance.

Specimens obtained by tube sampling or coring may be tested without trimming except for cutting the end surfaces plane and perpendicular to the longitudinal axis of the specimen, provided soil characteristics are such that no signi? A typical standard triaxial system with external data acquisition system includes: A different approach is required since the mercury level in the tailwater tube is not visible at equilibrium. D adtm 03 three days. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every?

Soil mechanics – Permeability test: Hydraulic conductivity varies with varying void ratio, which changes when the effective stress changes. Any variation observed in the data is just as likely to be due to specimen variation as to operator or laboratory testing variation.

When the initial and? The adoption of unsteady state measurements by using high-accuracy equipment along with the rigorous analyses for determining the hydraulic parameters this approach reduces testing duration according to Zhang et al. However, these test methods are only intended to be used when water is the permeant liquid. Temperatures outside this range may be used, however, the user would have to determine the specific gravity of mercury and R T see Where the sampling operation has caused disturbance of the soil, the disturbed material shall be trimmed.

  BIOLOGIA CELULAR Y MOLECULAR DE ROBERTIS DESCARGAR GRATIS PDF

Units other than seconds smeters masttm. If the soil core is not extruded vertically, care should be taken to avoid d084 stresses on the core due to gravity. If an d50084 pressure transducer or other measuring device is to be used during the test to measure pore pressures or applied hydraulic gradient, bleed any trapped air from the device.

The back pressure shall be maintained throughout the permeation phase.

ASTM D Standard

Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors. The test specimen shall be mounted immediately in the permeameter.

Rigid tubing, such as metallic or rigid thermoplastic tubing, or glass shall be used. This simulates the direction of? However, the use of small hydraulic gradients can lead to very long testing times for materials having low hydraulic conductivity less than about atsm 3 10?

In addition, it is either not feasible or too costly to produce multiple specimens that have uniform physical properties. After all visible air has been removed from the?

Continue permeation until at least four values of hydraulic conductivity are obtained over an interval of time in which: In addition, they are representative of the signi? In addition, for a given change in void ratio De the d50884 of change in k is much more dramatic in the overconsolidated range than in the normally consolidated range.

Follow us YouTube LinkedIn. These schematics present the basic components needed to meet the objectives of Method E. If the confining stress is less than the swell pressure, anomalous flow conditions my occur; for example, mercury column s move in the wrong direction. Test 9 Methods D and D describe two methods of compaction, but any other method speci? A permeant liquid used by some is a 0.

  KEITHLEY 224 MANUAL PDF

ASTM D5084

Additional de-airing may modify the concentration of this solution slightly, but this should not affect the hydraulic conductivity. The mass of specimens between g and g shall be determined to the nearest 0. However, measurement of the B coefficient as described in 9. More than system configurations are available depending on type of test, sample size, pressure system.

Active view current version of standard. D e5084 03 FIG. The mass and dimensions of the test specimen shall be determined to the tolerances given in 5. These hydraulic systems are as follows: Standard triaxial configuration with external data acquisition can be used for performing additional test such as CBR, Unconfined and CRS, Permeability.

Obtaining a specimen having a diameter of 36 mm 1.

Link to Active This link will always route to the current Active version of the standard. A pressure gage, electronic pressure transducer, or any other device of suitable accuracy shall measure pressures to a minimum of three signi?

If the number of signi? NOTE 15—The interval of time, Dt, can be measured directly using a stop watch or equivalent device, see The requirements outlined in 5.

Standard triaxial system with built-in digital data acquisition Standard triaxial System with built-in data acquisition is the ideal compact solution for performing standard triaxial tests such as effective and total stress.

Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. The device for pressurizing the cell may consist of a reservoir connected to the permeameter cell and partially?