HAAKE F3 PDF

Chillers / Circulators Haake F3-C Recirculating Heated Chiller Bath Haake F3C Refrigerated Circulator Haake F3-C Refrigerated Circulator. Find great deals for Haake F3 K Circulating Water Bath Chiller. Shop with confidence on eBay!. Find great deals for Haake F3-c Refrigerated Circulator V 50/60 Hz Great Shape. Shop with confidence on eBay!.

Author: Shagul Nikolar
Country: Solomon Islands
Language: English (Spanish)
Genre: Music
Published (Last): 28 May 2004
Pages: 310
PDF File Size: 9.74 Mb
ePub File Size: 17.95 Mb
ISBN: 288-4-91012-780-7
Downloads: 34884
Price: Free* [*Free Regsitration Required]
Uploader: Tujin

Sell now – Have one to sell? When certain conditions make draining necessary, please act safety conscious: Buyer shall be responsible for the safe and proper removal of any Goods purchased by Buyer.

Cable lengths and display fluctuations caused by them may be compensated with potentiometer 12 in two ways: Temperature control is achieved by controlled heating against constant cooling.

The liquid starts running out. All alcohols have a flash point below the average room temperature. Switch 5 on “Off not depressed and switch 28 to “intern”. The cooling unit V is not integrated within the safety circuit of the F3.

Perbunan is resistant against water, alcohol and most oils. Filling with Thermal Liquid The selection of the proper bath liquid thermal liquid influences the capacity of a temperature control unit decisively. Wear protective gloves and goggles when taking the lid off the bath vessel.

Haake F3 –

No returns or refunds will be permitted, unless authorized by the seller in writing. This instruction manual describes how this circulator is to be used.

  1995 MERCURY GRAND MARQUIS OWNERS MANUAL PDF

In order to avoid that the overtemperature sensor is triggered, it should be verified that Again, if this poses a problem, the automatic fan action can be turned off at switch 33! A wide radius should be used if turns have to be made! DO Actuate main switch 34 of the cooling unit. The F3 can be mounted prior to or after attaching the ahake to the bath.

The above table is an extract. ULUil Position grid and press in screws no turning required. I Only personnel with the particular know how should be allowed to carry out repairs. CD Press switch 1 of the temp, control unit.

A pin prevents the liquid from running out right away. The direction of the flow can be freely selected. When working with oil below room temperature: DIN Connection Sockets for: There are three fields of use: Close pressure port 18 and suction port 25 with the closing pieces and coupling nuts or, better still, connect the two nozzles with a short hose.

You are covered by the eBay Money Back Guarantee if you receive an item that is not as described in the haakke. Alcohol and oil, haaoe instance reduce these times by half when compared to water.

The compressor usually starts with a small jerk. Should haakr wish a different limitation, we will gladly inform you. It is absolutely mandatory that the overtemperature cutoff point is set lower than the flash point for the thermal liquid selected.

  A MEGGAZDAGODS TUDOMNYA PDF

Haake F3 series circulators manual ENG.pdf

The cut-off point must be sufficiently approx. Get the item you ordered or get your money back.

This necessitates the following: If you mark down the temperature of r3 display you will notice that, providing the uaake load and ambient remains unchanged, you will always have the same absolute temperature at this place of measurement.

H] Connect control cable with socket 15 4 of the temp, control unit and socket 35 of the cooling unit. Select a valid country. Every person enters the auction site at his or her own risk with notice of the condition of the premises and the activities that will be or have been conducted on the premises.

Adjust the potentiometer 12 until the temperature value previously shown in the internal control mode is reached again. HI The amount of flow should be set to a min. Function and Operating Elements 4. Only the F3 is switched off in case of malfunctions. Safety The safety features offer protection in case of so-called “individual errors” i.

H] Tilt F3 slightly and insert it into the opening as shown.